Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 209: 114237, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35447596

RESUMO

Kinetics measurements of antigen-antibody binding interactions are critical to understanding the functional efficiency of SARS-CoV-2 antibodies. Previously reported chaotrope-based avidity assays that rely on artificial disruption of binding do not reflect the natural binding kinetics. This study developed a chaotrope- and label-free biolayer interferometry (BLI) assay for the real-time monitoring of receptor binding domain (RBD) binding kinetics with SARS-CoV-2 spike protein in convalescent COVID-19 patients. An improved conjugation biosensor probe coated with streptavidin-polysaccharide (SA-PS) led to a six-fold increase of signal intensities and two-fold reduction of non-specific binding (NSB) compared to streptavidin only probe. Furthermore, by utilizing a separate reference probe and biotin-human serum albumin (B-HSA) blocking process to subtracted NSB signal in serum, this BLI biosensor can measure a wide range of the dissociation rate constant (koff), which can be measured without knowledge of the specific antibody concentrations. The clinical utility of this improved BLI kinetics assay was demonstrated by analyzing the koff values in sera of 24 pediatric (≤18 years old) and 63 adult (>18 years old) COVID-19 convalescent patients. Lower koff values for SARS-CoV-2 serum antibodies binding to RBD were measured in samples from children. This rapid, easy to operate and chaotrope-free BLI assay is suitable for clinical use and can be readily adapted to characterize SARS-CoV-2 antibodies developed by COVID-19 patients and vaccines.


Assuntos
Técnicas Biossensoriais , COVID-19 , Adolescente , Adulto , Anticorpos Neutralizantes , Anticorpos Antivirais , Criança , Humanos , Técnicas Imunológicas , Interferometria , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Estreptavidina
2.
Clin Chem ; 67(9): 1249-1258, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33914041

RESUMO

BACKGROUND: Low initial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody titers dropping to undetectable levels within months after infection have raised concerns about long-term immunity. Both the antibody levels and the avidity of the antibody-antigen interaction should be examined to understand the quality of the antibody response. METHODS: A testing-on-a-probe "plus" panel (TOP-Plus) was developed to include a newly developed avidity assay built into the previously described SARS-CoV-2 TOP assays that measured total antibody (TAb), surrogate neutralizing antibody (SNAb), IgM, and IgG on a versatile biosensor platform. TAb and SNAb levels were compared with avidity in previously infected individuals at 1.3 and 6.2 months after infection in paired samples from 80 patients with coronavirus disease 2019 (COVID-19). Sera from individuals vaccinated for SARS-CoV-2 were also evaluated for antibody avidity. RESULTS: The newly designed avidity assay in this TOP panel correlated well with a reference Bio-Layer Interferometry avidity assay (r = 0.88). The imprecision of the TOP avidity assay was <10%. Although TAb and neutralization activity (by SNAb) decreased between 1.3 and 6.2 months after infection, the antibody avidity increased significantly (P < 0.0001). Antibody avidity in 10 SARS-CoV-2 vaccinated individuals (median: 28 days after vaccination) was comparable to the measured antibody avidity in infected individuals (median: 26 days after infection). CONCLUSIONS: This highly precise and versatile TOP-Plus panel with the ability to measure SARS-CoV-2 TAb, SNAb, IgG, and IgM antibody levels and avidity of individual sera on one sensor can become a valuable asset in monitoring not only patients infected with SARS-CoV-2 but also the status of individuals' COVID-19 vaccination response.


Assuntos
Anticorpos Antivirais/sangue , Afinidade de Anticorpos/fisiologia , Técnicas Biossensoriais/métodos , COVID-19/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/patologia , COVID-19/virologia , Vacinas contra COVID-19/administração & dosagem , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Interferometria , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/isolamento & purificação , Fatores de Tempo , Adulto Jovem
3.
JAMA Netw Open ; 4(3): e214302, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33749770

RESUMO

Importance: Accumulating evidence suggests that children infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are more likely to manifest mild symptoms and are at a lower risk of developing severe respiratory disease compared with adults. It remains unknown how the immune response in children differs from that of adolescents and adults. Objective: To investigate the association of age with the quantity and quality of SARS-CoV-2 antibody responses. Design, Setting, and Participants: This cross-sectional study used 31 426 SARS-CoV-2 antibody test results from pediatric and adult patients. Data were collected from a New York City hospital from April 9 to August 31, 2020. The semiquantitative immunoglobin (Ig) G levels were compared between 85 pediatric and 3648 adult patients. Further analysis of SARS-CoV-2 antibody profiles was performed on sera from 126 patients aged 1 to 24 years. Main Outcomes and Measures: SARS-CoV-2 antibody positivity rates and IgG levels were evaluated in patients from a wide range of age groups (1-102 years). SARS-CoV-2 IgG level, total antibody (TAb) level, surrogate neutralizing antibody (SNAb) activity, and antibody binding avidity were compared between children (aged 1-10 years), adolescents (aged 11-18 years), and young adults (aged 19-24 years). Results: Among 31 426 antibody test results (19 797 [63.0%] female patients), with 1194 pediatric patients (mean [SD] age, 11.0 [5.3] years) and 30 232 adult patients (mean [SD] age, 49.2 [17.1] years), the seroprevalence in the pediatric (197 [16.5%; 95% CI, 14.4%-18.7%]) and adult (5630 [18.6%; 95% CI, 18.2%-19.1%]) patient populations was similar. The SARS-CoV-2 IgG level showed a negative correlation with age in the pediatric population (r = -0.45, P < .001) and a moderate but positive correlation with age in adults (r = 0.24, P < .001). Patients aged 19 to 30 years exhibited the lowest IgG levels (eg, aged 25-30 years vs 1-10 years: 99 [44-180] relative fluorescence units [RFU] vs 443 [188-851] RFU). In the subset cohort aged 1 to 24 years, IgG, TAb, SNAb and avidity were negatively correlated with age (eg, IgG: r = -0.51; P < .001). Children exhibited higher median (IQR) IgG levels, TAb levels, and SNAb activity compared with adolescents (eg, IgG levels: 473 [233-656] RFU vs 191 [82-349] RFU; P < .001) and young adults (eg, IgG levels: 473 [233-656] RFU vs 85 [38-150] RFU; P < .001). Adolescents also exhibited higher median (IQR) TAb levels, IgG levels, and SNAb activity than young adults (eg, TAb levels: 961 [290-2074] RFU vs 370 [125-697]; P = .006). In addition, children had higher antibody binding avidity compared with young adults, but the difference was not significant. Conclusions and Relevance: The results of this study suggest that SARS-CoV-2 viral specific antibody response profiles are distinct in different age groups. Age-targeted strategies for disease screening and management as well as vaccine development may be warranted.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Afinidade de Anticorpos/imunologia , Formação de Anticorpos/imunologia , COVID-19 , SARS-CoV-2 , Fatores Etários , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/imunologia , Teste Sorológico para COVID-19/métodos , Teste Sorológico para COVID-19/estatística & dados numéricos , Criança , Correlação de Dados , Estudos Transversais , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque/epidemiologia , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação
4.
medRxiv ; 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33564790

RESUMO

BACKGROUND: There is a concern that low initial SARS-CoV-2 antibody titers in individuals may drop to undetectable levels within months after infection. Although this may raise concerns over long term immunity, both the antibody levels and avidity of the antibody-antigen interaction should be examined to understand the quality of the antibody response. METHODS: A testing-on-a-probe-plus panel (TOP-Plus) was developed, which included a newly developed avidity assay built into the previously described SARS-CoV-2 TOP assays that measured total antibody (TAb), surrogate neutralizing antibody (SNAb), IgM and IgG on a versatile biosensor platform. TAb and SNAb levels were compared with avidity in previously infected individuals at 1.3 and 6.2 months post-infection in paired samples from 80 COVID-19 patients. RESULTS: The newly designed avidity assay in this TOP panel correlated well with a reference Bio-Layer Interferometry avidity assay (R=0.88). The imprecision of the TOP avidity assay was less than 9%. Although TAb and neutralization activity (by SNAb) decreased between 1.3 and 6.2 months post infection, the antibody avidity increased significantly (P < 0.0001).

5.
Biosens Bioelectron ; 178: 113008, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33515984

RESUMO

The association of mortality with the early humoral response to SARS-CoV-2 infection within the first few days after onset of symptoms (DAOS) has not been thoroughly investigated partly due to a lack of sufficiently sensitive antibody testing methods. Here we report two sensitive and automated testing-on-a-probe (TOP) biosensor assays for SARS-CoV-2 viral specific total antibodies (TAb) and surrogate neutralizing antibodies (SNAb), which are suitable for clinical use. The TOP assays employ an RBD-coated quartz probe using a Cy5-Streptavidin-polysacharide conjugate to improve sensitivity and minimize interference. Disposable cartridges containing pre-dispensed reagents require no liquid manipulation or fluidics during testing. The TOP-TAb assay exhibited higher sensitivity in the 0-7 DAOS window than a widely used FDA-EUA assay. The rapid and automated TOP-SNAb correlated well with two well-established SARS-CoV-2 virus neutralization tests. The clinical utility of the TOP assays was demonstrated by evaluating early antibody responses in 120 SARS-CoV-2 RT-PCR positive adult hospitalized patients. Higher TAb and SNAb positivity rates and more robust antibody responses at patient's initial hospital presentation were seen in inpatients who survived COVID-19 than those who died in the hospital. Survival analysis using the Cox Proportional Hazards Model showed that patients who had negative TAb and/or SNAb at initial hospital presentation were at a higher risk of in-hospital mortality. Furthermore, TAb and SNAb levels at presentation were inversely associated with SARS-CoV-2 viral load based on concurrent RT-PCR testing. Overall, the sensitive and automated TAb and SNAb assays allow the detection of early SARS-CoV-2 antibodies which associate with mortality.


Assuntos
Anticorpos Antivirais/sangue , Técnicas Biossensoriais/instrumentação , Teste Sorológico para COVID-19/instrumentação , COVID-19/imunologia , COVID-19/mortalidade , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/sangue , Técnicas Biossensoriais/estatística & dados numéricos , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Teste Sorológico para COVID-19/estatística & dados numéricos , Estudos de Coortes , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Neutralização/estatística & dados numéricos , Cidade de Nova Iorque/epidemiologia , Pandemias , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Adulto Jovem
6.
medRxiv ; 2020 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-33236020

RESUMO

The association of mortality with early humoral response to SARS-CoV-2 infection within the first few days after onset of symptoms (DAOS) has not been thoroughly investigated partly due to a lack of sufficiently sensitive antibody testing methods. Here we report two sensitive and automated testing-on-a-probe (TOP) biosensor assays for SARS-CoV-2 viral specific total antibodies (TAb) and surrogate neutralizing antibodies (SNAb), which are suitable for clinical use. The TOP assays employ an RBD-coated quartz probe using a Cy5-Streptavidin-polysacharide conjugate to improved sensitivity and minimize interference. Disposable cartridge containing pre-dispensed reagents requires no liquid manipulation or fluidics during testing. The TOP-TAb assay exhibited higher sensitivity in the 0-7 DAOS window than a widely used FDA-EUA assay. The rapid (18 min) and automated TOP-SNAb correlated well with two well-established SARS-CoV-2 virus neutralization tests. The clinical utility of the TOP assays was demonstrated by evaluating early antibody responses in 120 SARS-CoV-2 RT-PCR positive adult hospitalized patients. Higher baseline TAb and SNAb positivity rates and more robust antibody responses were seen in patients who survived COVID-19 than those who died in the hospital. Survival analysis using the Cox Proportional Hazards Model showed that patients who were TAb and SNAb negative at initial hospital presentation were at a higher risk of in-hospital mortality. Furthermore, TAb and SNAb levels at presentation were inversely associated with SARS-CoV-2 viral load based on concurrent RT-PCR testing. Overall, the sensitive and automated TAb and SNAb assays allow detection of early SARS-CoV-2 antibodies which associate with mortality.

7.
Clin Chim Acta ; 502: 128-132, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31883925

RESUMO

BACKGROUND: Daratumumab (DARA) is a fully human anti-CD38 IgG1-κ monoclonal antibody drug used in the treatment of multiple myeloma (MM). While serum protein electrophoresis (SPEP) is an important assay for diagnosis and monitoring of patients with MM, DARA can appear in the γ-region as a single band and interfere with the interpretation of SPEP results. An approach to detect the interference is measuring the quantity of DARA in serum samples and assessing its impact on SPEP results. Immunoassays based on label-free technologies, i.e. label-free immunoassays (LFIA's), can achieve real-time immunometric measurement without attaching a reporter molecule (enzyme, fluorophore, etc.) to the immunocomplex. The recorded time course of the immunocomplex formation allows for quantitation on initial binding rate, which facilitates rapid measurement within a few minutes. Based on the thin-film interferometry (TFI) technology, a rapid LFIA was established for the quantitation of DARA in serum samples. METHODS: The TFI-based LFIA for DARA was validated for imprecision (CV), accuracy, limit of quantitation (LOQ), and analytical measurement range (AMR). Interference to the LFIA was evaluated using a group of protein samples, as well as hemolytic, lipemic, and icteric clinical samples. RESULTS: The precision of the TFI-based LFIA's for DARA ranged from 6.5% to 10.7% (within-run CV), and 7.4% to 11.6% (between-run CV), with a bias of -2.1% to 10.1%. The LOQ was 10 µg/ml (n = 4, CV 9.8%), with an AMR ranging from the LOQ to 1000 µg/ml. The LFIA was used to measure 37 patient samples submitted for SPEP testing. The LFIA results were 100% consistent with the history of DARA use as documented in the medical record. CONCLUSIONS: The TFI-based LFIA was successful at accurately identifying DARA in serum samples and can be used to identify DARA interference in SPEP testing. This work demonstrates the applicability of label-free technologies, particularly the TFI technology, to clinical diagnostic needs. Given the simplicity and the speed of the testing process, the TFI technology provides a unique testing approach for the measurement of proteins in clinical samples.


Assuntos
Anticorpos Monoclonais/sangue , Análise Química do Sangue , Proteínas Sanguíneas/química , Imunoensaio , Eletroforese , Humanos , Interferometria
8.
Clin Biochem ; 73: 35-43, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31247187

RESUMO

BACKGROUND: Cardiac troponin (cTn) is a complex of three subunits (T, I, and C), with some studies reporting that ~5-10% is cytosolic and unbound ('free'). It has been hypothesized that free cTn is released before complex and before or without cell death dependent on the severity of ischemia. In this context, new generation assays that can discriminate free, binary (IC) and ternary (TIC) complex forms may aid to differentiate between type 1 myocardial infarction (MI) and cTn elevations due to different etiologies, e.g. demand ischemia and type 2 MI. METHODS: Serial plasma samples from six type 1 MI patients and twenty-seven patients with other cTnI elevations, e.g. due to demand ischemia and type 2 MI, were analyzed using high-sensitivity ET Healthcare Pylon assays for total cTnI, complex cTnI (IC and TIC), and cTnTIC. The specificity of the anti-cTnT antibody in the cTnTIC assay was such that only full-size cTnTIC is detected. In vitro stability of different cTnI forms was assessed by spiking free cTnI and cTnTIC in cTnI-free serum, incubating at 4 or 37 °C, and measuring different cTnI forms over 0-182 h. Presence of cytosolic free cTnI was evaluated on fixed rat cardiac tissue using an antibody against free cTnI. RESULTS: Pylon assays for total and complex cTnI tracked well over time with each other and gave similar results, both for type 1 MI and non-type 1 MI patients, indicating that the vast majority was complex cTnI. As a minority of complex cTnI was full-size cTnTIC, this indicated that complex cTnI mainly consisted of a degraded form of cTnTIC (low-molecular weight cTnTIC) and/or cTnIC. Full-size cTnTIC was more abundant in early compared to late samples. In vitro studies indicated that free cTnI and cTnTIC are not stable at 37 °C (28% and 11% recovery after 24 h, respectively) and this is also true to some extent for cTnTIC at 4 °C (60% recovery after 24 h). Free cTnI was not readily detected in rat cardiac tissue. CONCLUSIONS: In agreement with type 1 MI, cTnI in samples of patients with cTnI elevations due to other etiologies is found predominantly as complex cTnI, of which some is full-size cTnTIC. In most cases, assays for total and complex cTnI indicated there was little free cTnI; however, its presence cannot be completely excluded, due to the inability of its direct measurement and limited stability.


Assuntos
Infarto do Miocárdio/sangue , Miocárdio/metabolismo , Troponina I/sangue , Troponina T/sangue , Animais , Linhagem Celular , Feminino , Humanos , Masculino , Infarto do Miocárdio/classificação , Ratos , Ratos Nus
9.
Comb Chem High Throughput Screen ; 12(8): 791-800, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19758119

RESUMO

The analysis of biomolecular interactions is key in the drug development process. Label-free biosensor methods provide information on binding, kinetics, concentration, and the affinity of an interaction. These techniques provide real-time monitoring of interactions between an immobilized ligand (such as a receptor) to an analyte in solution without the use of labels. Advances in biosensor design and detection using BioLayer Interferometry (BLI) provide a simple platform that enables label-free monitoring of biomolecular interactions without the use of flow cells. We review the applications of BLI in a wide variety of research and development environments for quantifying antibodies and proteins and measuring kinetics parameters.


Assuntos
Técnicas Biossensoriais/métodos , Interferometria/métodos , Anticorpos/química , Reações Antígeno-Anticorpo , Técnicas Biossensoriais/instrumentação , Descoberta de Drogas/métodos , Cinética , Ligantes , Proteínas/química , Coloração e Rotulagem , Fatores de Tempo
10.
Mol Ther ; 6(5): 576-83, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12409255

RESUMO

This study was designed to test the hypothesis that transcutaneous ultrasound (US) exposure may augment the transfection efficiency and biological outcome associated with nonviral DNA gene transfer. Hindlimb muscles of New Zealand White rabbits were transfected with the reporter plasmid pCMV-beta, with or without US exposure. Optimization studies employed US exposure at various frequencies, mechanical indices, duty cycles, durations of exposure, and exposure time points. Based on these results, we explored the effect of US exposure on nonviral gene transfer of vascular endothelial growth factor (VEGF, phVEGF165) to promote neovascularization of ischemic hindlimbs. Ultrasound at 1 MHz, 100 W/cm(2), 6% duty cycle, and 5 minutes exposure time, applied immediately following DNA injection, was found to be the most effective among the settings tested, increasing beta-galactosidase expression approximately 20 fold. Compared with US exposure alone, or phVEGF165 only, phVEGF165 + US exposure yielded a statistically significant improvement in revascularization, as determined by calf blood pressure ratio, angiographic score, intravascular Doppler blood flow, and capillary/myocyte ratio. These data demonstrate that ultrasound, when applied directly after intramuscular gene transfer, significantly increases transfection efficiency in vivo. The biological significance of this finding was confirmed by augmented limb perfusion in response to US exposure and naked VEGF DNA.


Assuntos
DNA , Técnicas de Transferência de Genes , Terapia Genética/métodos , Músculo Esquelético/metabolismo , Ultrassom , Animais , Capilares/metabolismo , Genes Reporter , Hemodinâmica , Isquemia , Masculino , Células Musculares/metabolismo , Neovascularização Patológica , Plasmídeos/metabolismo , Coelhos , Transfecção , Doenças Vasculares/terapia , beta-Galactosidase/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...